Optical behavior of the eye implanted with extreme intraocular lens powers
Renan F Oliveira1, Liberdade C Salerno1, Michael Mimouni2
1Research, Development & Innovation Department, VISSUM Instituto Oftalmológico, Alicante, Spain; Clinical Research Fellow, VISSUM Instituto Oftalmológico, Alicante, Spain; Sadalla Amin Ghanem Eye Hospital, Joinville, SC, Brazil.
Purpose:
To evaluate the induced ocular aberrations after cataract surgery with extreme low- powered and high-powered spherical monofocal intraocular lenses (IOLs) using a new pyramidal wavefront sensor aberrometer.
Setting:
Vissum Instituto Oftalmológico, Alicante, Spain.
Design:
Prospective observational comparative study.
Methods:
This study included patients who had cataract surgery with implantation of a spherical monofocal IOL. The patients were divided into three groups according to the IOL power. Group 1: +20 diopters (D) to +23 D; Group 2: less than +10 D; and Group 3: +29 D or more. Assessment after 3 months included: uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, contrast sensitivity function test (Ginsburg), corneal aberrometry, and total ocular aberrometry with a pyramidal wavefront sensor aberrometer (Osiris) for 4.0 mm, 4.5 mm, and 5.0 mm pupil diameters.
Results:
The study comprised 88 eyes of 56 patients. There were no differences between all groups in terms of refractive error, corneal aberrometry, or total ocular higher-order aberrations at any analyzed pupil diameter. The ocular spherical aberration (SA) was not significantly different between groups with a 4.0 mm pupil. The SA was significantly lower in Group 2 when compared with Group 1 and Group 3 for both 4.5 mm (P = .01 and P = .001, respectively) and 5.0 mm (P = .002 and P = .002, respectively). There was no significant difference in SA between Group 1 (+20 D to 23 D) and Group 3 (≥+29 D) at any analyzed pupil diameter. Higher SA did not correlate to lower contrast sensitivity.
Conclusions:
Despite the theoretical evidence, only a negligible amount of clinically insignificant aberrations were induced by high-powered positive IOLs. Low-powered IOLs did not induce significant levels of SAs.
More Related Videos
Related Concept Videos
Power
Absolute and Local Extreme Values
Power System Distribution
The transmission system is designed...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Power and Energy
Power, defined as the time rate of expending or absorbing energy, is quantified in units called watts (W). The relation between power and energy is mathematically given as
Average Power