Related Experiment Video
Updated: Jan 23, 2026

Endoscopic Septoplasty with Limited Two-line Resection: Minimally Invasive Surgery for Septal Deviation
Published on: June 20, 2018
Analysis of Linear and Angular Deviations of Implants Installed With a Tomographic-Guided Surgery Technique: A
Guilherme José Pimentel Lopes de Oliveira1, Wagner de Souza Mattos2, Mariana Albaricci2
1Department of Periodontology, Dental School, Universidade Federal de Uberlândia (UFU), Uberlândia, Brazil.
Computerized tomography (CT)-guided surgery accurately places dental implants. This study found high accuracy in both the maxilla and mandible, with minimal deviations, ensuring straight implant placement.
Area of Science:
- Oral and Maxillofacial Surgery
- Dental Implantology
- Medical Imaging
Background:
- Fully edentulous maxilla and mandible present challenges for dental implant placement.
- Computerized tomography (CT)-guided surgery offers a potential solution for precise implant positioning.
Purpose of the Study:
- To evaluate the linear and angular deviations of dental implants placed using CT-guided surgery.
- To compare implant accuracy between the maxilla and mandible.
Main Methods:
- 18 patients with fully edentulous arches received 115 implants via CT-guided surgery.
- Virtual planning based on tomographic examination and prosthesis.
- Postoperative tomography used to measure deviations between planned and actual implant positions.
Main Results:
- No significant differences in linear or angular deviations between maxillary and mandibular implants.
- A trend towards greater linear deviations in apical vs. coronal regions and posterior vs. anterior regions observed.
- CT-guided surgery demonstrated high accuracy, enabling straight implant pillar placement.
Conclusions:
- CT-guided surgery is a highly accurate technique for dental implant placement in fully edentulous patients.
- The technique ensures precise implant positioning, minimizing deviations and facilitating prosthetic rehabilitation.
Related Concept Videos
Relating Angular And Linear Quantities - I
When comparing the linear and rotational variables individually, the linear variable of position has physical units of meters, whereas the angular position variable has dimensionless units of radians, as it is the ratio of two lengths. The linear velocity...
Relating Angular And Linear Quantities - II
Voltammetric Techniques: Linear-Scan (E vs Time)
Variation: Normal Distribution, Range, and Standard Deviation
Standard Deviation
Mean Absolute Deviation
Let us consider a dataset containing the number of unsold cupcakes in five shops: 10, 15, 8, 7, and 10. Initially, calculate the sample mean. Then calculate the deviation, or the difference, between each data value and the mean. Next, the absolute values of these deviations are added and divided by the sample size to...