Related Experiment Video
Updated: Jan 23, 2026

An In Vitro Assay to Detect tRNA-Isopentenyl Transferase Activity
Published on: October 8, 2018
A label-free fluorescence method based on terminal deoxynucleotidyl transferase and thioflavin T for detecting
Mingjian Chen1, Changbei Ma2, Ying Yan1
1School of Life Sciences, Central South University, Changsha, 410013, China.
Abstract:
Prostate-specific antigen (PSA) is the only biomarker for the diagnosis of prostate cancer. So the PSA screening test is very important due to the high occurrence of prostate cancer in men. In this work, a label-free fluorescent method was developed based on terminal deoxynucleotidyl transferase (TdT) and G-quadruplex-thioflavin T complex for detecting PSA. In the absence of PSA, the PSA aptamer can be used as the primer for TdT extension reactions, resulting in the formation of G-quadruplexes and generation of strong fluorescent signals. After the addition of PSA, the PSA-aptamer complex prevented the TdT extension reaction due to steric hindrance, thus resulting in a poor fluorescent signal. The assay showed a wide linear range (0.1 to 80 pg/mL) and a detection limit of 0.086 pg/mL (S/N = 3). It also has good specificity for PSA determination and gives satisfactory results when applied to biological samples. Conceivably, its merits such as good selectivity and high sensitivity indicate that the proposed method has a promising application potential in the clinical diagnosis and treatment of prostate cancer. Graphical abstract.
More Related Videos
07:37Using Terminal Transferase-mediated dUTP Nick End-labelling TUNEL and Caspase 3/7 Assays to Measure Epidermal Cell Death in Frogs with Chytridiomycosis
Published on: May 16, 2018
08:27Detection of Human Leukocyte Antigen Biomarkers in Breast Cancer Utilizing Label-free Biosensor Technology
Published on: March 24, 2015
Related Concept Videos
Termination of Translation
Termination of Translation
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Drag Force and Terminal Speed
Clinically Relevant Drug Product Specifications: Methods of Establishment