A new in-line X-ray phase-contrast computed tomography reconstruction algorithm based on adaptive-weighted
Yuqing Zhao1, Dongjiang Ji2, Yingpin Chen3
1School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin 300070, People's Republic of China.
Abstract:
In-line X-ray phase-contrast computed tomography (IL-PCCT) is a valuable tool for revealing the internal detailed structures in weakly absorbing objects (e.g. biological soft tissues), and has a great potential to become clinically applicable. However, the long scanning time for IL-PCCT will result in a high radiation dose to biological samples, and thus impede the wider use of IL-PCCT in clinical and biomedical imaging. To alleviate this problem, a new iterative CT reconstruction algorithm is presented that aims to decrease the radiation dose by reducing the projection views, while maintaining the high quality of reconstructed images. The proposed algorithm combines the adaptive-weighted anisotropic total p-variation (AwaTpV, 0 < p < 1) regularization technique with projection onto convex sets (POCS) strategy. Noteworthy, the AwaTpV regularization term not only contains the horizontal and vertical image gradients but also adds the diagonal image gradients in order to enforce the directional continuity in the gradient domain. To evaluate the effectiveness and ability of the proposed algorithm, experiments with a numerical phantom and synchrotron IL-PCCT were performed, respectively. The results demonstrated that the proposed algorithm had the ability to significantly reduce the artefacts caused by insufficient data and effectively preserved the edge details under noise-free and noisy conditions, and thus could be used as an effective approach to decrease the radiation dose for IL-PCCT.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...