A simple and efficient method to measure beam attenuation through a radiotherapy treatment couch and immobilization
Omemh Bawazeer1,2, Sisira Herath3, Sivananthan Sarasanandarajah4,3,5
1Discipline of Medical Radiations, RMIT University, Melbourne, Australia. s3470562@student.rmit.edu.au.
Abstract:
We propose a simple and efficient method to measure beam attenuation in one or two dimensions using an amorphous silicon electronic portal imaging device (a-Si EPID). The proposed method was validated against ionization chamber measurements. Beam attenuation through treatment couches (Varian Medical Systems) and immobilization devices (CIVCO Radiotherapy, USA) was examined. The dependency of beam attenuation on field size, photon energy, thickness of the couch, and the presence of a phantom were studied. Attenuation images were derived by computing the percentage difference between images obtained without and with a couch or immobilization devices determining the percentage of attenuation at the center and the mean attenuation. The beam attenuation measurements obtained with an a-Si EPID and an ionization chamber agreed to within ± 0.10 to 1.80%. No difference was noted between the center and mean of an attenuated image for a small field size of 5 × 5 cm2, whereas a large field size of 15 × 15 cm2 exhibited differences of up to 1.13%. For an 18 MV beam, the a-Si EPID required additional build-up material for accurate assessment of beam attenuation. The a-Si EPID could measure differences in beam attenuation through an image guided radiotherapy (IGRT) couch regardless of the variabilities in couch thickness. Interestingly, the addition of a phantom reduced the magnitude of attenuation by approximately 1.20% for a field size of 15 × 15 cm2. A simple method is proposed that provides the user with beam attenuation data in either 2D or 1D within a few minutes.
Related Concept Videos
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Principal Stresses in a Beam
Analyzing principal stresses is crucial, especially in...
Beams with Symmetric Loadings
The M/EI...