Complex Susceptibilities and Chiroptical Effects of Collagen Measured with Polarimetric Second-Harmonic Generation

Ahmad Golaraei1,2,3, Lukas Kontenis4,5, Kamdin Mirsanaye2,3

  • 1Princess Margaret Cancer Centre, University Health Network, Toronto, M5G 1L7, Canada.

Scientific Reports
|August 30, 2019
PubMed

Related Concept Videos

Simultaneous Label-Free Autofluorescence Multi-Harmonic Microscopy09:19

Simultaneous Label-Free Autofluorescence Multi-Harmonic Microscopy

This protocol presents a step-by-step guide for the Simultaneous Label-free Autofluorescence Multi-harmonic (SLAM) microscopic technique, including details on how to generate the laser light source, prepare a tissue sample, conduct imaging, and analyze the data. SLAM advances nonlinear microscopy by measuring four complementary label-free contrasts to investigate the tissue microenvironment.
586
Reproducibility and Harmonization in Research Using Biological Standards: The Example of Platelet Agonist Collagen-Related Peptide04:50

Reproducibility and Harmonization in Research Using Biological Standards: The Example of Platelet Agonist Collagen-Related Peptide

Here we present a method to standardize the platelet agonist collagen-related peptide cross-linked (CRP-XL) using light transmission aggregometry. While the protocol is targeted at platelet function, the experimental process can be applied to most biological molecules and bioassays to ensure scientific rigor and...
1.6K
Second Harmonic Generation Signals in Rabbit Sclera As a Tool for Evaluation of Therapeutic Tissue Cross-linking (TXL) for Myopia12:25

Second Harmonic Generation Signals in Rabbit Sclera As a Tool for Evaluation of Therapeutic Tissue Cross-linking (TXL) for Myopia

This protocol describes techniques for evaluating chemical cross-linking of the rabbit sclera using second harmonic generation imaging and differential scanning...
8.2K
Harmonic Nanoparticles for Regenerative Research09:23

Harmonic Nanoparticles for Regenerative Research

Protocol details are provided for in vitro labeling human embryonic stem cells with second harmonic generating nanoparticles. Methodologies for hESC investigation by multi-photon microscopy and their differentiation into cardiac clusters are also...
12.1K
Harmonic Mean01:09

Harmonic Mean

The arithmetic mean is usually skewed towards the larger values in the data set. Therefore, to avoid this inherent bias towards smaller values, the harmonic mean is used.
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
3.6K
Second Harmonic Generation Imaging in a Rat Model to Study Tubulin Defects02:40

Second Harmonic Generation Imaging in a Rat Model to Study Tubulin Defects

Source: Piazza, V., et al., Label-Free Non-Linear Optics for the Study of Tubulin-Dependent Defects in Central Myelin. J. Vis. Exp. (2023)This video demonstrates the procedure for imaging microtubule abnormalities in a rat brain tissue slice using a two-photon excitation microscope. It employs second harmonic generation (SHG) signals to detect tubulin defects and reduced myelin...
383