Quantifying hydraulic and water quality uncertainty to inform sampling of drinking water distribution systems

David Hart1, J Santiago Rodriguez2, Jonathan Burkhardt3

  • 1Sandia National Laboratories, Albuquerque, NM.

Journal of Water Resources Planning and Management
|September 11, 2019
PubMed

Related Concept Videos

Quality of Water01:19

Quality of Water

In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
506
Water Quality Analysis via Indicator Organisms08:17

Water Quality Analysis via Indicator Organisms

Source: Laboratories of Dr. Ian Pepper and Dr. Charles Gerba -The University of Arizona
Demonstrating Author: Luisa Ikner
Water quality analysis monitors anthropogenic influences such as pollutants, nutrients, pathogens, and any other constituent that can impact the water’s integrity as a resource. Fecal contamination contributes microbial pathogens that threaten plant, animal, and human health with disease or illness. Increasing water demands and strict quality standards require that...
31.1K
EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. I. Collection of Virus Samples10:48

EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. I. Collection of Virus Samples

EPA Method 1615 uses an electropositive filter to concentrate enteroviruses and noroviruses in environmental and drinking waters. This manuscript describes the procedure for collecting samples for Method 1615...
12.7K
Testing Water Quality01:14

Testing Water Quality

When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
372
VirWaTest, A Point-of-Use Method for the Detection of Viruses in Water Samples13:32

VirWaTest, A Point-of-Use Method for the Detection of Viruses in Water Samples

Here we present VirWaTest, which is a simple, affordable and portable method for the concentration and detection of viruses from water samples at the point of...
9.0K
Hydraulic Jumps09:15

Hydraulic Jumps

Source: Alexander S Rattner and Mahdi Nabil; Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA
When liquid flows along an open channel at high velocity, the flow can become unstable, and slight disturbances can cause the liquid upper surface to transition abruptly to a higher level (Fig. 1a). This sharp increase in the liquid level is called a hydraulic jump. The increase in the liquid level causes a reduction in the average flow velocity....
42.2K