Related Experiment Video
Updated: Jan 19, 2026

Laboratory Drop Towers for the Experimental Simulation of Dust-aggregate Collisions in the Early Solar System
Published on: June 5, 2014
Simulation of Drop-Size Distribution During Dropwise and Jumping Drop Condensation on a Vertical Surface:
Kimberly A Stevens1, Julie Crockett1, Daniel Maynes1
1Department of Mechanical Engineering , Brigham Young University , 350 Engineering Building , Provo , Utah 84602 , United States.
Abstract:
Accurate models for condensation heat transfer are necessary to improve condenser design. Drop-size distribution is an important aspect of heat transfer modeling that is difficult to measure for small drop sizes. The present work uses a numerical simulation of condensation which incorporates the possibility of coalescence and coalescence-induced jumping over a range of drop sizes. Results of the simulation are compared with previous theoretical models and the impact of the assumptions used in those models is explored. In particular, previous drop-size distribution models may predict heat transfer rates less accurately for high contact angles and for coalescence-induced jumping since coalescence occurs over a range of drop sizes and does not always result in departure. The influence of various input parameters (nucleation site distribution approach, nucleation site density, contact angle, maximum drop size, heat transfer modeling to individual drops, and minimum jumping size) on the drop-size distribution and overall heat transfer rate is explored. Assignment of the nucleation site spatial distribution and heat transfer model affect both the drop-size distribution and predicted overall heat transfer rate. Results from the simulation suggest that, when the contact angle is large (as on superhydrophobic surfaces) and no coalescence-induced jumping occurs, the heat transfer may not be as sensitive to the maximum drop-size as previously supposed. Furthermore, this work suggests that when coalescence-induced jumping occurs, reducing the maximum drop size may not always increase heat transfer since drops similar in size to those removed by coalescence-induced jumping can contribute significantly to the overall heat transfer rate.
Related Concept Videos
09:44Laboratory Drop Towers for the Experimental Simulation of Dust-aggregate Collisions in the Early Solar System
08:45Glass-Based Devices to Generate Drops and Emulsions
09:20Picoinjection of Microfluidic Drops Without Metal Electrodes
Excess Pressure Inside a Drop and a Bubble
Hydraulic Jumps
When liquid flows along an open channel at high velocity, the flow can become unstable, and slight disturbances can cause the liquid upper surface to transition abruptly to a higher level (Fig. 1a). This sharp increase in the liquid level is called a hydraulic jump. The increase in the liquid level causes a reduction in the average flow velocity....
07:32Pool-Boiling Heat-Transfer Enhancement on Cylindrical Surfaces with Hybrid Wettable Patterns