Related Experiment Video
Updated: Jan 1, 2026

Avocado Sample Preparation Using the QuEChERS Method with Ammonium Formate for Pesticide Analysis
Published on: December 8, 2023
Multi-residue analytical method for trace detection of new-generation pesticides in vegetables using gas
Nguyen Dang Giang Chau1, Nguyen Van Hop1, Hoang Thai Long1
1Department of Chemistry, College of Sciences, Hue University, Hue City, Vietnam.
Abstract:
A GC-MS/MS method with low solvent consumption and easy operation was developed to simultaneously determine ten new-generation pesticides, namely fenobucarb, acetochlor, pretilachlor, fipronil, trifloxystrobin, fluazifop-p-butyl, isoprothiolane, tebuconazole, cypermethrin and difenoconazole in leafy vegetables. Influences from ultrasonic sample extraction and the clean-up steps to reduce matrix effects were investigated. Under suitable conditions, good linearity (deviation of back calculated concentration from true concentration lower than 20%) was achieved for all studied pesticides; the method detection limits (MDLs) ranged from 1.4 to 3.6 ng g-1 wet weight. For mustard green and green onion the method yielded good recoveries at two spiking levels (201 and 100 ng g-1) ranging from 80% to 111% (n = 5). The repeatability, expressed as relative standard deviation (RSD), was lower than 11% (n = 5). The method was successfully used to quantify pesticide residues in 207 vegetable samples (green onions, mustard greens, and lettuce) collected in Thua Thien Hue and Quang Binh Provinces, Central Vietnam. The insecticide cypermethrin was found at critical levels in 98% of the vegetable samples. Green onions had high pesticide residues with a significant number of samples containing pesticides at concentrations exceeding the maximum residue levels (MRLs).
More Related Videos
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...