Related Experiment Video
Updated: Dec 31, 2025

Early Detection of Cyanobacterial Blooms and Associated Cyanotoxins using Fast Detection Strategy
Published on: February 25, 2021
Calibration Changes to Terra MODIS Collection-5 Radiances for CERES Edition 4 Cloud Retrievals
Sunny Sun-Mack1, Patrick Minnis1, Yan Chen1
1Science Systems and Applications, Inc., Hampton, VA 23666.
None:
Previous research has revealed inconsistencies between the Collection 5 (C5) calibrations of certain channels common to the Terra and Aqua MODerate-resolution Imaging Spectroradiometers (MODIS). To achieve consistency between the Terra and Aqua MODIS radiances used in the Clouds and the Earth's Radiant Energy System (CERES) Edition 4 (Ed4) cloud property retrieval system, adjustments were developed and applied to the Terra C5 calibrations for channels 1-5, 7, 20, and 26. These calibration corrections were developed independently of those used for MODIS Collection 6 (C6) data, which became available after the CERES Ed4 processing had commenced. The comparisons demonstrate that the corrections applied to the Terra C5 data for CERES Edition 4 generally resulted in Terra-Aqua radiance consistency that is as good as or better than that of the C6 datasets. The C5 adjustments resulted in more consistent Aqua and Terra cloud property retrievals than seen in the previous CERES edition. Other calibration artifacts were found in one of the corrected channels and in some of the uncorrected thermal channels after Ed4 began. Where corrections were neither developed nor applied, some artifacts are likely to have been introduced into the Ed4 cloud property record. For example, the degradation in the Aqua MODIS 0.65-microm channel in both the C5 and C6 datasets affects trends in cloud optical depth retrievals. Thus, despite the much-improved consistency achieved for the Terra and Aqua datasets in Ed4, the CERES Ed4 cloud property datasets should be used cautiously for cloud trend studies because of those remaining calibration artifacts.
More Related Videos
09:55Surface Renewal: An Advanced Micrometeorological Method for Measuring and Processing Field-Scale Energy Flux Density Data
Published on: December 12, 2013
12:26Integrating Remote Sensing with Species Distribution Models; Mapping Tamarisk Invasions Using the Software for Assisted Habitat Modeling SAHM
Published on: October 11, 2016
Related Concept Videos
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Flame Photometry: Lab
Influence of Earth's Curvature and Atmospheric Refraction on Leveling