Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Chemometric decomposition of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry data
Derrick V Gough1, Sonia Schӧneich1, Robert E Synovec1
1Department of Chemistry, Box 351700, University of Washington, Seattle, WA, 98195, USA.
Abstract:
Partial modulation in the negative pulse mode was optimized for comprehensive two-dimensional gas chromatography (GC × GC) coupled to time-of-flight mass spectrometry (TOFMS). With partial modulation in the negative pulse mode, a flow of auxiliary carrier gas is applied through a pulse valve to a T-junction joining the first (1D) and second (2D) dimension columns for nearly all of the modulation period (PM). This results in dilution of the 1D eluate, followed by briefly turning off the pulse valve for a specified pulse width (pw), effectively "injecting" undiluted 1D eluate onto the 2D column. The raw data has the appearance of 2D separations superimposed on top of the 1D separation. While high peak capacity GC × GC data are produced, there are challenges that needed to be addressed regarding the use of chemometrics for analyte decomposition, identification, and quantification. Herein, these data analysis challenges are addressed using multivariate curve resolution - alternating least squares (MCR-ALS). An isothermal separation of a 15-component mixture of similar compounds is obtained in 20 s using a PM = 250 ms and a pw = 6 ms. Various peak overlap situations were purposely produced to facilitate the chemometric method demonstration. The MCR-ALS chromatographic loadings (peak profiles) were used to determine retention times (tR) and width-at-base (Wb) in both separation dimensions. MCR-ALS readily decomposed 1D × 2D regions for analytes with severe 1D overlap if they were fully resolved on 2D. Decomposition was more challenging for analytes severely overlapped on both GC × GC dimensions when their spectra were similar, though ultimately all 15 compounds were successfully decomposed. Additionally, the 2D concentration peak profiles obtained via MCR-ALS are demonstrated to be reliable for identification and quantifiable. The predicted versus prepared concentration values are in good agreement for two representative analytes, with percent deviation values of -5.6% (±2.2%) for 1-hexene, and 1.8% (±3.4%) for 2-pentanone.
More Related Videos
08:22Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Tandem Mass Spectrometry
MALDI-TOF Mass Spectrometry
Mass Spectrum: Interpretation
Gas Chromatography: Types of Detectors-II