Influence of corneal spherical aberration on prediction error of the Haigis-L formula
Woong-Joo Whang1, Young-Sik Yoo2, Hyun-Seung Kim3
1Department of Ophthalmology, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Abstract:
The purpose of this study is to investigate the relationships between corneal asphericity and Haigis-L formula prediction errors in routine cataract surgery after refractive surgery for myopic correction. This retrospective study included 102 patients (102 eyes) with a history of previous PRK or LASIK and cataract surgery. Axial length, anterior chamber depth, and central corneal power were measured using the optical biometer. On the anterior corneal surface, Q-value, spherical aberration, and ecentricity at 6.0 and 8.0 mm were measured using a rotating Scheimpflug camera. The postoperative refractive outcome at 6 months, mean error, and mean absolute error were determined. Correlation tests were performed to determine the associations between pre-cataract surgery data and the prediction error. The Q-values for 6.0 and 8.0 mm corneal diameter were 1.57 ± 0.70 (range: 0.03~3.44), and 0.82 ± 0.5 (range: -0.10~-2.66). The spherical aberration for 6.0 and 8.0 mm diameter was 1.16 ± 0.39 µm (range: 0.24~2.08 µm), and 3.69 ± 0.87 µm (range: 0.91~5.91 µm). eccentricity for 6.0 and 8.0 mm diameter was -1.22 ± 0.31 (range: -1.85 to -0.17), and -0.82 ± 0.39 (range: -1.63 to 0.32). The spherical aberration for 8.0 mm cornea diameter showed the highest correlations with the predicion error (r = 0.750; p < 0.001). When the modified Haigis-L formula considering spherical aberration for 8.0 mm produced smaller values in standard deviation of mean error (0.45D versus 0.68D), mean absolute error (0.35D versus 0.55D), and median absolute error (0.31D versus 0.51D) than the Haigis formula. Corneal asphericity influences the predictive accuracy of the Haigis-L formula. The accuracy was enhanced by taking into consideration the corneal spherical aberration for the 8.0 mm zone at pre-cataract surgery state.
Related Concept Videos
Focusing of Light in the Eye
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
Gauss's Law: Spherical Symmetry
Geometry of Hyperbolas
Spherical Coordinates
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...