Related Experiment Video
Updated: Dec 23, 2025

Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
Published on: June 27, 2014
Derivative UV/Vis spectroelectrochemistry in a thin-layer regime: deconvolution and simultaneous quantification of
Fabiola Olmo1, Jesus Garoz-Ruiz1, Alvaro Colina1
1Department of Chemistry, Universidad de Burgos, Plaza Misael Bañuelos s/n, E-09001, Burgos, Spain.
Abstract:
In this work, UV/Vis spectroelectrochemistry (SEC), in a thin-layer regime and parallel configuration, is selected to solve a complex mixture that contains dopamine (DA), ascorbic acid (AA) and uric acid (UA). These molecules, like many other biological compounds, are assuming a highly important place in analytical and biomedical fields due to the fundamental role that they play in human metabolism. In addition, low or high levels of these compounds are associated with diseases such as Parkinson's disease. For this reason, the quantification of these biomolecules is becoming increasingly critical. However, some drawbacks must be overcome, because the three molecules coexist in the human body, and the species are subject to mutual interference. In fact, they are all oxidized at similar potentials, and their UV/Vis absorption bands overlap, greatly complicating their quantification. For this reason, derivative SEC together with suitable chemometric tools such as PARAFAC are proposed to solve this complex matrix. This technique allows us to separate the contribution of each of these molecules present in a sample and to quantify all of them, achieving high resolution and reproducibility. Besides, detection limits at the micromolar level are achieved for DA, AA and UA in mixture solutions. This work thus demonstrates the great potential for derivative potentiodynamic SEC combined with the appropriate chemometric tools in solving complex mixtures, a field where SEC is still taking the first steps. Graphical abstract.
More Related Videos
11:44Using Cyclic Voltammetry, UV-Vis-NIR, and EPR Spectroelectrochemistry to Analyze Organic Compounds
Published on: October 18, 2018
10:48Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Related Concept Videos
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
UV–Vis Spectrometers
UV–Vis Spectroscopy: Woodward–Fieser Rules
UV–Vis Spectroscopy: Molecular Electronic Transitions
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...