Related Experiment Video
Updated: Dec 14, 2025

Synthesis and Microdiffraction at Extreme Pressures and Temperatures
Published on: October 7, 2013
X-ray pulse stretching after diffraction
1Institute of Physics, Academy of Sciences of the Czech Republic, Na Slovance 2, 18221 Praha 8, Czech Republic.
Abstract:
The development of ultrashort X-ray pulse sources requires optics that keep the pulse length as short as possible. One source of pulse stretching is the penetration of the pulse into a crystal during diffraction. Another source is the inclination of the intensity front when the diffraction is asymmetric. The theory of short X-ray pulse diffraction has been well developed by many authors. As it is rather complicated, it is sometimes difficult to foresee the pulse behavior (mainly stretching) during diffraction in various crystal arrangements. In this article, a simple model is suggested that gives a qualitatively similar shape to the diffracted pulse which follows from exact theory. It allows proposal of what experimental arrangement is optimal to minimize the pulse stretching during diffraction. First, the effect of pulse stretching due to penetration into a crystal surface is studied. On the basis of this, the pulse profile change during diffraction by two crystals, either symmetric or asymmetric, is predicted.
More Related Videos
08:44Measurements of Long-range Electronic Correlations During Femtosecond Diffraction Experiments Performed on Nanocrystals of Buckminsterfullerene
Published on: August 22, 2017
10:36Stress Distribution During Cold Compression of Rocks and Mineral Aggregates Using Synchrotron-based X-Ray Diffraction
Published on: May 20, 2018
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
IR Frequency Region: X–H Stretching
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
X-ray Imaging