Minimal Tradeoff and Ultimate Precision Limit of Multiparameter Quantum Magnetometry under the Parallel Scheme

Zhibo Hou1, Zhao Zhang1, Guo-Yong Xiang1

  • 1CAS Key Laboratory of Quantum Information, University of Science and Technology of China, Hefei 230026, People's Republic of China and CAS Center For Excellence in Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei 230026, People's Republic of China.

Related Concept Videos

NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
969
Paramagnetism01:30

Paramagnetism

Paramagnets are materials with unpaired electrons that possess a finite magnetic moment. In the absence of a magnetic field, these moments are randomly oriented, and thus the net moment is zero. Under an external field, a torque acting on the moments tends to align them along the field's direction. However, the random thermal motion of electrons produces a torque opposite to the external field and tries to disorient the moments. These two competing effects align only a few moments along the...
2.9K
Magnetic Vector Potential01:15

Magnetic Vector Potential

In electrostatics, the electric field can be written as the negative gradient of the potential. In magnetostatics, the zero divergence of the magnetic field ensures that the magnetic field can be expressed as the curl of a vector potential. This potential is known as the magnetic vector potential.
Consider an ideal solenoid with n turns per unit length and radius R. If I is the current through the solenoid, the magnetic field inside the solenoid is expressed as the product of vacuum...
1.4K
Magnetic Susceptibility and Permeability01:31

Magnetic Susceptibility and Permeability

In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
2.1K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.4K
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
560