Related Experiment Video
Updated: Dec 13, 2025

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Global longitudinal strain for prediction of ventricular arrhythmia in patients with heart failure
Mohammad Hossein Nikoo1,2,3, Razieh Naeemi4, Alireza Moaref1,2
1Department of Cardiovascular Medicine, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
Aims:
Currently, the ejection fraction [left ventricular ejection fraction (LVEF)] is the main criterion used for implanting implantable cardioverter defibrillators (ICDs) for primary prevention. However, many of ICD receivers would not have an event and do not have any gains from the device. Consequently, improving the discrimination strategies is needed. Here, we aimed at assessing the role of global longitudinal strain (GLS) for such purpose.
Methods And Results:
Seventy ischaemic or dilated cardiomyopathy cases characterized by LVEF ≤ 40% with a previously implanted ICD were enrolled. LVEF and GLS amounts were evaluated using 3D echocardiography. The occurrence of ventricular arrhythmias was checked by analysing the ICD history. Mean follow-up period of patients was 1.8 ± 0.6 years. There was a significant difference in the amount of GLS in arrhythmic cases compared with non-arrhythmic ones (-6.97 ± 3.06 vs -11.82 ± 4.25; P < 0.001). This difference was found in both ischaemic and dilated cardiomyopathy groups. A GLS below -10 cm/s could predict the occurrence of a ventricular event by 90% specificity and 72.2% sensitivity (area under the curve = 0.84, P < 0.001). While 27.39 (69.2%) patients with GLS below -10 cm/s had a ventricular event, only 3.31 (9.6%) of the patients with GLS above -10 had an event) P < 0.001). Those patients with a GLS ≥ 17 cm/s never experienced a ventricular arrhythmia.
Conclusions:
Global longitudinal strain is a more accurate predictor of ventricular arrhythmias in patients with reduced LVEF. Whether it may help in selecting more appropriate patients for ICD implantation or not should be evaluated within a randomized trial in the future.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Heart Failure IV: Classification and Diagnostic Evaluation
Heart Failure II: Pathophysiology
Pathophysiology of Heart Failure
Heart Failure III: Clinical Manifestations
Heart Failure I: Introduction
Dysrhythmias V: Evaluating Dysrhythmias