Measuring the Weak Mixing Angle in the DUNE Near-Detector Complex.
André de Gouvêa1, Pedro A N Machado2, Yuber F Perez-Gonzalez1,2,3
1Department of Physics & Astronomy, Northwestern University, Evanston, Illinois 60208, USA.
Physical Review Letters
|August 16, 2020
Summary
The DUNE experiment will precisely measure neutrino-electron scattering to constrain electron weak couplings. DUNE-PRISM enhances sensitivity, enabling a 2% measurement of the weak mixing angle (sin²θW).
Area of Science:
- Particle Physics
- Neutrino Physics
- Electroweak Interactions
Background:
- The DUNE experiment aims for high precision in neutrino physics.
- Neutrino-electron scattering offers a unique probe of electroweak interactions.
Purpose of the Study:
- To assess the sensitivity of the DUNE-PRISM near detector to neutrino-electron scattering.
- To determine the impact of DUNE-PRISM on constraining electron weak couplings.
- To measure the weak mixing angle (sin²θW) at low energy scales.
Main Methods:
- Utilizing precision measurements of neutrino-electron scattering at the DUNE experiment.
- Employing the movable DUNE-PRISM near detector, oriented perpendicular to the beam line.
- Analyzing data from seven years of DUNE operation.
Main Results:
- DUNE-PRISM significantly enhances the ability to constrain electron weak couplings.
- A precision of approximately 2% for the weak mixing angle (sin²θW) is achievable.
- The study explores combining neutrino-electron scattering with neutrino trident production.
Conclusions:
- The DUNE experiment, particularly with DUNE-PRISM, will provide crucial insights into fundamental electroweak parameters.
- Precision measurements of neutrino-electron scattering are vital for probing beyond the Standard Model physics.
- The weak mixing angle measurement will be a significant contribution to low-energy particle physics.
Related Concept Videos
Mass Analyzers: Common Types
1.2K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.2K
Mass Analyzers: Overview
1.4K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.4K


