Related Experiment Video
Updated: Dec 10, 2025

Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Impact of lossy compression of X-ray projections onto reconstructed tomographic slices
Federica Marone1, Jakob Vogel1, Marco Stampanoni1
1Swiss Light Source, Paul Scherrer Institut, Villigen, Switzerland.
Abstract:
Modern detectors used at synchrotron tomographic microscopy beamlines typically have sensors with more than 4-5 mega-pixels and are capable of acquiring 100-1000 frames per second at full frame. As a consequence, a data rate of a few TB per day can easily be exceeded, reaching peaks of a few tens of TB per day for time-resolved tomographic experiments. This data needs to be post-processed, analysed, stored and possibly transferred, imposing a significant burden onto the IT infrastructure. Compression of tomographic data, as routinely done for diffraction experiments, is therefore highly desirable. This study considers a set of representative datasets and investigates the effect of lossy compression of the original X-ray projections onto the final tomographic reconstructions. It demonstrates that a compression factor of at least three to four times does not generally impact the reconstruction quality. Potentially, compression with this factor could therefore be used in a transparent way to the user community, for instance, prior to data archiving. Higher factors (six to eight times) can be achieved for tomographic volumes with a high signal-to-noise ratio as it is the case for phase-retrieved datasets. Although a relationship between the dataset signal-to-noise ratio and a safe compression factor exists, this is not simple and, even considering additional dataset characteristics such as image entropy and high-frequency content variation, the automatic optimization of the compression factor for each single dataset, beyond the conservative factor of three to four, is not straightforward.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT

