Night-to-night variability in obstructive sleep apnea using peripheral arterial tonometry: a case for multiple night

Samuel Tschopp1, Wilhelm Wimmer1,2, Marco Caversaccio1

  • 1Department of Otorhinolaryngology, Head and Neck Surgery, Inselspital, University Hospital and University of Bern, Bern, Switzerland.

Summary

Night-to-night variability in obstructive sleep apnea (OSA) severity is significant, even with peripheral arterial tonometry (PAT). Multiple nights of testing are recommended for accurate OSA diagnosis and to avoid misclassification.

Related Concept Videos

Sleep Apnea01:21

Sleep Apnea

Sleep apnea is a condition where breathing stops intermittently during sleep, often leading to significant health issues. Each episode can last from 10 to 20 seconds or more and is frequently accompanied by a brief arousal from sleep. This disturbance, largely unnoticed by the individual, can lead to severe daytime fatigue. Commonly, individuals seek help after being informed by their partners about loud snoring and noticeable breathing pauses during sleep.
The condition is more prevalent among...
283
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation01:21

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
138
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1.1K
Pulse Oximetry01:24

Pulse Oximetry

Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.0K