Related Experiment Video
Updated: Nov 11, 2025

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Examining Use of Dual Point Temperature Display in Servo-Control With Early Preterm Infants
Robin B Dail1, Abbas S Tavakoli, Sherry L Moseley
1University of South Carolina, College of Nursing, Columbia (Drs Dail and Tavakoli); and Department of Neonatology, Pediatrics, East Carolina University, Greenville, North Carolina (Mss Moseley and Bergstedt and Drs Kuehn and Chang).
Background:
Previously, we recorded periods of time with foot higher than abdominal temperatures in association with infection in preterm infants. Monitoring dual temperatures may be an important tool to assess infant instability. Currently, incubators cannot measure and display dual temperatures in servo-control mode.
Purpose:
To examine the usability of GE Healthcare's Giraffe OmniBed with research software to measure, display, and record dual temperatures, and their differences while in servo-control. In addition, nurses' perceptions of the use and display of dual temperatures and differences were evaluated.
Methods:
A multiple-case, mixed-methods design. Abdominal and foot temperatures were measured, displayed, and stored for 28 days for 14 preterm infants. Nurses were surveyed for satisfaction and preferences with the dual temperature display. Nurses noted abnormal temperature differences and infant condition in bedside journals.
Results:
Study infants were 26 to 31 weeks of gestational age and 670 to 1410 g. Abdominal, foot, and the abdominal-foot temperature difference was measured, recorded, and downloaded successfully in all infants over all days. Nurses liked using dual temperature display with the abdominal-foot temperature difference. Surveys indicated preferences for larger displays and alarms for abnormal values. Thermal instability, stimulation, and thermistor detachment were associated with abnormal thermal gradients. Two exemplar cases are presented.
Implications For Practice:
Monitoring dual temperatures adds information to the clinical assessment.
Implications For Research:
Studies are needed to examine relationships between abnormal thermal gradients and infections, infant stability, and nursing care along with the underlying physiologic mechanisms. Studies are needed for wireless dual temperature monitoring.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...