Related Experiment Video
Updated: Nov 10, 2025

Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts
Published on: August 13, 2014
[A study of the effect of hot and cold gas perfusion sequence on caloric test results]
Chao Wen1, Qiaomei Deng1, Qiang Liu1
1Department of Otorhinolaryngology Head and Neck Surgery,Tianjin First Central Hospital,Institute of Otolaryngology of Tianjin,Key Laboratory of Auditory Speech and Balance Medicine,Key Clinical Discipline of Tianjin(Otolaryngology.
Abstract:
Objective: To study whether the warm/cold air injection sequence affects the test results in the caloric test, and provide a basis for the specification and quality control of the caloric test. Methods:Video nystagmography and warm and cold air stimulation apparatus were applied for caloric test. Thirty healthy volunteers (60 ears) were divided into two groups of 15 (30 ears) each. The first group was given cold air stimulation followed by warm air stimulation, and the second group was given heat followed by cold. The differences in nystagmus maximal slow phase velocity (SPV), semicircular canal paresis (CP) and dominant preponderance (DP) were compared between the two groups of subjects under different perfusion sequences of caloric test. Results:The intensity of nystagmus evoked by subjects in group 1 (cold first and then warm) and group 2 (warm first and then cold) were similar. Paired t-test showed that intra-group analysis of the SPV values of the two groups, comparison of the intensity of nystagmus evoked by different temperatures of the same ear or different sides of ear with the same temperature, the difference was not statistically significant (all P>0.05). Independent samples t-test showed that between-group analysis of SPV values of two groups, the intensity of nystagmus induced by the same and different temperature stimuli in the ipsilateral ear, the difference was not statistically significant (all P>0.05). Independent samples t-test showed that the CP values of the two groups were analyzed between groups, and the difference was not statistically significant (all P>0.05). Independent samples t-test showed that DP values of both groups were in the normal range and the difference was not statistically significant (all P>0.05). Conclusion:Different perfusion sequences of warm and cold air do not affect the results of caloric tests, and the order of warm and cold air stimulation is not the normative and quality control research direction of caloric test.
More Related Videos
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
Related Concept Videos
Constant Pressure Calorimetry
Calorimetry
Constant Volume Calorimetry
Joule-Thomson Effect
This experiment forces high-pressure gas through a throttle valve or a porous plug to a lower-pressure region. The gas expands as it passes through to...
Temperature and Thermal Equilibrium
The concept of temperature has evolved from the common concepts of hot and cold. The scientific definition of temperature explains more than just our sense of hot and cold. Temperature is operationally defined as the quantity measured with a thermometer. Furthermore, temperature is...
Efficiency of The Carnot Cycle