On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
[Determination of hydrazine in workplace air by gas chromatography with large bore capillary column]
1Jiangsu Provincial Center for Disease Prevention and Control, Nanjing 210009, China.
Abstract:
Objective: To determine hydrazine quantitatively in workplace air by gas chromatography with large bore capillary column. Methods: In October 2019, hydrazine in the air was adsorbed by acid silica gel tube sampling and desorped using sulfuric acid solution. After derivatization with furfural and extraction, the content of hydrazine was determined by DM-FFAP capillary column gas chromatography with flame ionization detector. Results: The linear regression equation was y=353.8x+21.2 (r=0.9998) between 0.1-2.0 μg/ml of target concentration. The detection limit was 0.030 μg/ml. The lower limit of quantification was 0.100 μg/ml. If 15 L air sample was collected, the minimum detection concentration was 0.004 mg/m(3) and the minimum quantitative concentration was 0.013 mg/m(3) respectively. The average desorption efficiency was 86.5%-89.4%. The recovery was 94.4%-97.1%. The relative standard deviation was 1.6%-4.9%. Hydrazine and furfural derivative was 2-furaldehyde hydrazine. Conclusion: The method has symmetrical peak shape of hydrazine derivatives chromatographic peaks, short analysis time, easy operation, and is suitable for the determination of the concentration of hydrazine in the air in the workplace.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...