Diagnosis of Fluorosis by Analysis of Fluoride Content in Body Fluids Using Ion Selective Electrode Method
1Fluorosis Foundation of India (Camping & Working for JICA Funded 'Fluorosis Mitigation Programme' in Nagaur District, Rajasthan, India), New Delhi, India. nisithkm@gmail.com.
Abstract:
Analysis of fluoride in body fluids (urine and serum) is essential for fluorosis diagnosis. Although 24-h urine collection is adopted to assess community defluoridation/fluoride supplementation program/research studies, but not feasible for Clinical/Pathological laboratories. Patients are reluctant to bring 24-h urine samples. Hence, spot urine samples are collected in clean, dry polypropylene bottles (not glass) without any preservative and analyzed on the same day by the Ion analyzer (ISE method). Equal volumes of Total Ionic Strength Adjustment Buffer (TISAB) solution are then added with body fluids before analysis and mixed well to eliminate interference from other ions besides pH adjustment and to provide a constant ionic strength. Results are reported as mg of Fluoride/l (ppm). High fluoride level in body fluids is an indication of confirmed cases of fluorosis. Two interventions, e.g. withdrawal of fluoride intake and intake of nutritive diet was introduced for prevention and control of fluorosis. The present study is to provide useful guidelines for monitoring of fluorosis disease in human beings, those who are at the risk of fluoride exposure.
More Related Videos
09:24Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
14:55Analysis of Minerals Produced by hFOB 1.19 and Saos-2 Cells Using Transmission Electron Microscopy with Energy Dispersive X-ray Microanalysis
Published on: June 24, 2018
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...