Quantifying groundwater flow variability in a poorly cemented fractured sandstone aquifer to inform in situ
Carlos H Maldaner1, Jonathan D Munn1, Bradley A Green2
1G360 Institute for Groundwater Research, University of Guelph, Canada.
Abstract:
This study applies innovative methods to characterize and quantify the magnitude of groundwater flow in a fractured and variably cemented sandstone aquifer to inform an in-situ remediation strategy for trichloroethene (TCE) contamination. A modified active-distributed temperature sensing (A-DTS) approach in which fiber optic cables were permanently grouted in the borehole was used to quantify groundwater flow rates. Two additional tracer tests were conducted: 1) fluorescein tracer injection followed by rock coring and sampling for visual mapping and porewater analysis, and 2) deployment of passive flux meters in conventional monitoring wells to evaluate groundwater velocity and mass flux distributions. Forced gradient injection of fluorescein tracer suggests a dual porosity flow system wherein higher rates of groundwater flow occur within discrete features including highly permeable bedding planes and fractures, with slower flow occurring within the rock matrix. Tracer was observed and detected in the unfractured matrix porewater >1.5 m away from the injection well. Beyond this distance, >6 m radially away from the injection hole, tracer was primarily detected within and adjacent to high transmissivity fractures serving as preferential flow paths. The Darcy flux calculated using active distributed temperature sensing (A-DTS) shows depth-discrete values ranging from 7 to 60 cm/day, with average and median values of 23 and 17 cm/day, respectively. Passive Flux Meters (PFMs) deployed in three conventional monitoring wells with slotted screens and sand filter packs showed groundwater flux values ranging from 2 to 11 cm/day, with an overall average of 4 cm/day and are likely biased low due to spreading in the sand pack. The study results were used to inform an in-situ remediation system design including the proposed injection well spacing and the amendment delivery approach. In addition, the results were used to build confidence in the viability of delivering an oxidant to the rock matrix via advective processes. This is important because 1) the matrix is where the majority of the TCE mass occurs, and 2) it provides insights on processes that directly affect remedial performance expectations given advective delivery to preferential pathways and the matrix overcomes diffusion only conditions.
Related Concept Videos
Rapidly Varying Flow
Gradually Varying Flow
Uniform Depth Channel Flow: Problem Solving
Uniform Depth Channel Flow
Underflow Gates
Porosity in Cement Paste
The balance of water to cement in the mix is...