1The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, The State and Shandong Province Joint Key Laboratory of Translational Cardiovascular Medicine, Department of Cardiology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China.
Background:
Left atrial appendage occlusion (LAAO) is usually performed via the guidance of procedural transesophageal echocardiography (TEE) companied by general anesthesia (GA).
Objective:
To investigate the feasibility and safety of LAAO guided by procedural fluoroscopy only.
Methods:
The patients eligible for LAAO were enrolled into the current study and received implantation of either Watchman device or LAmbre device. The procedure was carried out with procedural fluoroscopy only and no companied GA; the position, shape, and leakage of the device were assessed by contrast angiography. TEE was performed after 3-month follow-up to evaluate the thrombosis, and leakage of device.
Results:
Ninety-seven patients with atrial fibrillation (AF) with either Watchman device (n = 49) or LAmbre device (n = 48) were consecutively enrolled. Watchman device group was of lower CHA2 DS2 -VASc and HAS-BLED scores compared with LAmbre device groups (p < .05); the two groups had similar distributions of other baseline characteristics (p > .05), including procedural success rate (98.0% vs. 97.9%), mean procedure time, mean fluoroscopy time, total radiation dose, contrast medium dose, percentage of peri-device leakage. Pericardial effusions requiring intervention occurred in two of the Watchman group. TEE follow-up found no patient with residual leakage ≥5 mm at 3 months and no device related thrombosis (DRT). During the 22.0 ± 11.1 months follow-up, two patients experienced ischemic stroke.
Conclusions:
LAAO with the procedural imaging of fluoroscopy only exhibited the promising results of efficacy and safety. A prospective randomized multicenter study would be required to verify the observations in this study.