Related Experiment Video
Updated: Oct 26, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[Multicenter Evaluation of Cine Angiography and Digital Subtraction Angiography Dose Rate for Various Angiography
Kazuya Takeda1, Toshihiro Hayashi2, Koshi Sakiyama3
1Department of Radiology, Sakakibara Heart Institute.
Abstract:
We conducted a nationwide multicenter survey of various interventional radiology (IVR) procedures. Data were collected from 385 X-ray systems in 126 institutions, including 432 cine programs and 380 digital subtraction angiography (DSA) programs for diagnostic catheterization, percutaneous coronary intervention (PCI), ablation, transcatheter aortic valve implantation (TAVI), neurologic IVR, thorax IVR, abdominal IVR, and endovascular therapy (EVT). Fluoroscopic and cine dose rates were 10.1 mGy/min and 110.7 mGy/min, respectively, whereas for DSA programs, the median fluoroscopic and DSA dose rates were 8.0 mGy/min and 224.8 mGy/min, respectively. The DSA dose rate was more than twice the cine dose rate. The largest difference between dose rates was for diagnostic catheterization, which had a cine dose rate of 142.6 mGy/min and a fluoroscopic dose rate of 12.6 mGy/min (by a factor of 12.5), followed by EVT, which had a DSA dose rate of 216.0 mGy/min and a fluoroscopic dose rate of 7.7 mGy/min (by a factor of 29.6). The smallest difference between dose rates was for TAVI, which had a cine dose rate of 96.8 mGy/min and a fluoroscopic dose rate of 12.0 mGy/min (by a factor of 8.9), followed by neurologic IVR, which had a DSA dose rate of 227.9 mGy/min and a fluoroscopic dose rate of 9.6 mGy/min (by a factor of 22.6). Compared with the fluoroscopic dose rates, the cine dose rates were 9-13 times higher and the DSA dose rates were 22-30 times higher; the DSA dose rates were more than double the cine dose rates.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography