Related Experiment Video
Updated: Oct 25, 2025

07:36
Studying Cavitation Enhanced Therapy
Published on: April 9, 2021
5.5K
[New Design of Revivent TC System].
Ben Wang1, Tianping Yao2, Zhengyu Ma2
1Shanghai MicroPort Co. Ltd., Shanghai, 201203.
Summary
Left ventricular aneurysm (LVA) treatment is challenging. A new revivent TC system design offers accurate force measurement and simpler surgery for LVA reconstruction, improving patient outcomes.
Area of Science:
- Cardiovascular Medicine
- Biomedical Engineering
- Medical Device Design
Background:
- Left ventricular aneurysm (LVA) is a frequent complication following myocardial infarction.
- Current treatments for LVA often lack efficacy or demand significant surgical expertise and patient resilience.
- Minimally invasive medical devices present a promising avenue for LVA treatment and left ventricular reconstruction.
Purpose of the Study:
- To address the limitations of existing revivent TC systems in treating LVA.
- To propose an improved revivent TC system design focused on clinical needs.
- To enhance the accuracy of force measurement and surgical simplicity in LVA repair.
Main Methods:
- Review of existing revivent TC system and identification of its clinical application defects.
- Conceptualization and design of a novel revivent TC system incorporating enhanced force measurement capabilities.
- Evaluation of the proposed design for its potential to simplify surgical procedures for LVA.
Main Results:
- The study identified specific shortcomings in the current revivent TC system's performance.
- A new design was developed, featuring precise force measurement for improved control during LVA treatment.
- The proposed design aims to streamline the surgical process, making LVA reconstruction more accessible.
Conclusions:
- The novel revivent TC system design holds potential to overcome the limitations of current treatments for LVA.
- Accurate force measurement and simplified surgical steps are key advancements for effective LVA reconstruction.
- This improved system could enhance treatment options for patients suffering from myocardial infarction complications.
Keywords:
force-measuring deviceleft ventricular aneurysmleft ventricular reconstructionrevivent TC systemMore Related Videos
Related Concept Videos
Design Example: Automobile Ignition System
387
The automobile's ignition system plays a vital role by ensuring the timely ignition of the fuel-air mixture in each cylinder. This ignition is facilitated by a spark plug, which is composed of two electrodes separated by an air gap. A spark forms across this air gap when a substantial voltage is generated between the electrodes, leading to the ignition of the fuel.
One can generate a large voltage using a car battery of 12 volts with the help of inductors. Inductors are known for opposing...
One can generate a large voltage using a car battery of 12 volts with the help of inductors. Inductors are known for opposing...
387
PD Controller: Design
409
In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
409
PI Controller: Design
656
Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
656
Design Example
417
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
417
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
1.1K
Oxygen therapy is a pivotal aspect of medical care, particularly for patients with respiratory ailments. Two prominent oxygen-delivering systems include the Venturi mask and the transtracheal oxygen catheter.
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
1.1K
Electrical Systems
520
In electrical engineering, the analysis of networks composed of passive linear components — resistors (R), capacitors (C), and inductors (L) — is fundamental. These components are organized into circuits where the relationship between input and output can be analyzed using transfer functions. The transfer function of an RLC circuit, which relates the voltage across a capacitor to the input voltage, can be derived using Kirchhoff's laws.
To derive the transfer function, consider...
To derive the transfer function, consider...
520

