Conducting Multiple Imaging Modes with One Fluorescence Microscope
Published on: October 28, 2018
10.0K
High-contrast multifocus microscopy with a single camera and z-splitter prism.
Sheng Xiao1, Howard Gritton1, Hua-An Tseng1
1Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, Massachusetts 02215, USA.
Optica
|September 17, 2021
Summary
This study introduces a multifocus optical microscopy technique using a z-splitter prism for faster, simpler 3D imaging. The method enhances image contrast and offers versatile applications in biological and biomedical research.
Area of Science:
- Biomedical Imaging
- Optical Microscopy
- Cell Biology
Background:
- 3D volumetric imaging in optical microscopy is crucial but often limited by speed and complexity.
- Existing methods struggle with efficient acquisition of high-resolution 3D biological data.
Purpose of the Study:
- To develop a simplified multifocus imaging strategy for rapid and efficient 3D volumetric imaging.
- To enhance image contrast and enable quasi-optical sectioning in microscopy.
- To create a versatile imaging system applicable to various modalities.
Main Methods:
- Implemented a multifocus imaging strategy using a z-splitter prism to distribute image stacks onto a single camera.
- Developed an extended-volume 3D deconvolution algorithm to suppress out-of-focus fluorescence.
- Configured z-splitter for prioritizing speed or field-of-view.
Main Results:
- Simultaneous recording of 3D image stacks on a single camera.
- Significant improvement in image contrast and reduction of background noise.
- Demonstrated adaptability to fluorescence, phase-contrast, and darkfield imaging.
Conclusions:
- The developed multifocus imaging system offers a simple, versatile, and high-performance solution for 3D biological imaging.
- The technique provides quasi-optical sectioning capabilities, improving image quality.
- This approach is suitable for a broad range of biological and biomedical applications.
Related Concept Videos
Confocal Fluorescence Microscopy
17.6K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
17.6K
Super-resolution Fluorescence Microscopy
10.3K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
10.3K
Phase Contrast and Differential Interference Contrast Microscopy
11.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
11.2K