Electrochemical behaviour of uranium at a tripolyphosphate modified ITO electrode

Xiangyang Hou1, Jeffrey R McLachlan1, Christopher J Dares1

  • 1Florida International University, Department of Chemistry and Biochemistry, 11200 SW 8th St., Miami, FL 33199, USA. cdares@fiu.edu.

Chemical Communications (Cambridge, England)
|October 4, 2021
PubMed

Related Concept Videos

Electrodeposition01:08

Electrodeposition

Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
786
Ladder Diagrams: Redox Equilibria01:30

Ladder Diagrams: Redox Equilibria

Ladder diagrams are useful tools for understanding redox equilibrium reactions, especially the effects of concentration changes on the electrochemical potential of the reaction. The vertical axis in the redox ladder diagrams represents the electrochemical potential, E. The area of predominance is demarcated using the Nernst equation.
Consider the Fe3+/Fe2+ half-reaction, which has a standard-state potential of +0.771 V. At potentials more positive than +0.771 V, Fe3+ predominates, whereas Fe2+...
561
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
343
Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
1.0K