Related Experiment Video
Updated: Oct 13, 2025

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
The Electrospray (ESI) and Flowing Atmosphere-Pressure Afterglow (FAPA) Mass Spectrometry Studies of Nitrophenols
Mateusz Pawlaczyk1, Michał Cegłowski1, Rafał Frański1
1Faculty of Chemistry, Adam Mickiewicz University in Poznań, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland.
Abstract:
The functional silica-based materials functionalized with a strong nitrogen base TBD (SiO2-TBD) deposited via a linker or with a basic poly(amidoamine) dendrimer containing multiple terminal amine groups -NH2 (SiO2-EDA) and functional polymers containing a strong phosphazene base (Polymer-Phosphazene) or another basic poly(amidoamine) dendrimer (PMVEAMA-PAMAM) were tested as sorbents dedicated to a mixture of nitrophenols (p-nitrophenol and 2-methoxy-5-nitrophenol), which are analogs of nitrophenols used in plant growth biostimulants. The adsorptive potential of the studied materials reached 0.102, 0.089, 0.140, and 0.074 g of the nitrophenols g-1, for SiO2-TBD, SiO2-EDA, polymer-phosphazene, and PMVEAMA-PAMAM, respectively. The sorptive efficiency of the analytes, i.e., their adsorption on the functional materials, the desorption from the obtained [(sorbent)H+ - nitrophenolates-] complexes, and interactions with the used soil, were monitored using mass spectrometry (MS) technique with electrospray (ESI) and flowing atmosphere-pressure afterglow (FAPA) ionizations, for the analysis of the aqueous solutions and the solids, respectively. The results showed that the adsorption/desorption progress is determined by the structures of the terminal basic domains anchored to the materials, which are connected with the strength of the proton exchange between the sorbents and nitrophenols. Moreover, the conducted comprehensive MS analyses, performed for both solid and aqueous samples, gave a broad insight into the interactions of the biostimulants and the presented functional materials.
More Related Videos
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing...
Mass Spectrometry of Amines
Amines undergo fragmentation through α cleavage, producing nitrogen-containing cations—iminium ions—and alkyl radicals. Mass spectra of aromatic and cyclic aliphatic amines exhibit...
2° Amines to N-Nitrosamines: Reaction with NaNO2
High-Performance Liquid Chromatography: Types of Detectors
Electrophilic Aromatic Substitution: Nitration of Benzene

