Related Experiment Video
Updated: Oct 10, 2025

In Vitro Evaluation of The Effects Of Er,Cr:YSGG and Diode Lasers Used on Titanium Cylinder
Published on: June 6, 2025
Effects of heat on seven endodontic sealers
Daniel Chavarria-Bolanos1, Takashi Komabayashi2, Ivy Shen2
1Faculty of Dentistry, University of Costa Rica.
Purpose:
To examine the microscopic surface features, chemical composition, and thermodynamic profile of seven endodontic sealers (AH Plus, Adseal, MTA-Fillapex, RoekoSeal, GuttaFlow 2, GuttaFlow BioSeal, and EndoRez) exposed to high-temperature changes using an endodontic obturation device.
Methods:
The thermal properties were examined using scanning calorimetry (DSC) and thermogravimetric analysis (TGA). Then, six disc-shaped specimens of each sealer were prepared and divided into two groups - a room temperature group and a heat exposure group - for analysis of surface and chemical changes using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS).
Results:
DSC analysis showed that AH Plus had the highest exothermal signal (122.9°C), while TGA analysis showed that MTA-Fillapex was most affected by increased temperature (32.4% mass loss at 230ºC). SEM analysis showed that while AH Plus and GuttaFlow BioSeal maintained their surface integrity after heat exposure, the EDS profiles demonstrated changes in the chemical composition of the sealers after heat exposure for 5 s. High-temperature exposure had a negative impact on the properties of five of the sealers (Adseal, MTA-Fillapex, RoekoSeal, GuttaFlow 2, and EndoRez).
Conclusion:
AH Plus and GuttaFlow BioSeal showed minimal changes upon high-temperature exposure, suggesting their suitability for thermal endodontic obturation techniques.
More Related Videos
Related Concept Videos
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...