Hollow Core Bragg Fiber-Based Sensor for Simultaneous Measurement of Curvature and Temperature
Zongru Yang1, Weihao Yuan1, Changyuan Yu1
1Photonics Research Centre, Department of Electronic and Information Engineering, The Hong Kong Polytechnic University, Hong Kong, China.
Abstract:
In this paper, the hollow core Bragg fiber (HCBF)-based sensor based on anti-resonant reflecting optical waveguide (ARROW) model is proposed and experimentally demonstrated for simultaneous measurement of curvature and temperature by simply sandwiching a segment of HCBF within two single-mode fibers (SMFs). The special construction of a four-bilayer Bragg structure provides a well-defined periodic interference envelope in the transmission spectrum for sensing external perturbations. Owing to different sensitivities of interference dips, the proposed HCBF-based sensor is capable of dual-parameter detection by monitoring the wavelength shift. The highest curvature sensitivity of the proposed sensor is measured to be 74.4 pm/m-1 in the range of 1.1859-2.9047 m-1 with the adjusted R square value of 0.9804. In the meanwhile, the best sensitivity of temperature sensing was detected to be 16.8 pm/°C with the linearity of 0.997 with temperature range varying from 25 to 55 °C. Furthermore, with the aid of the 2 × 2 matrix, the dual demodulation of curvature and temperature can be carried out to realize the simultaneous measurement of these two parameters. Besides dual-parameter sensing based on wavelength shift, the proposed sensor can also measure temperature-insensitive curvature by demodulating the intensity of resonant dips.
More Related Videos
08:23A Random-displacement Measurement by Combining a Magnetic Scale and Two Fiber Bragg Gratings
Published on: September 30, 2019
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Related Concept Videos
Measurements of Strain
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Thermal Strain
Temperature Dependent Deformation
Constant Pressure Calorimetry
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...