Related Experiment Video
Updated: Oct 10, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Design of a wearable device for physiological parameter monitoring in a COVID setting
Abstract:
The study focuses on the realization of an accurate device for the detection of different physiological parameters. It has been realized a simple portable system containing the necessary electronics and ensuring the monitoring of the blood oxygenation, the body temperature, the air quality, the respiratory rate and the ECG. The main processing unit consists in a Raspberry Pi Zero W connected to the Healthy Pi4. The latter provides the interface for the clinical pulse-oxymeter while the measures of temperature and quality air are provided using the I2C protocol. The Bluetooth module is finally used to provide the ECG and blood rate data. The collected data are elaborated using Matlab and Python. To evaluate the accuracy of the realized device some experimental tests have been conducted on different subjects, comparing subjects working in Covid area with others resting at home. In both cases the monitoring time was 4 hours. Results have shown good performances of the system, detecting accurately the differences of the parameters values between the two situations. The usability of the device was assessed by administering a questionnaire to the healthcare personnel involved in the experimentation. The outcome shows a good usability of the system as well as an acceptable dressing time.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

