NATIONWIDE SURVEY OF RADIATION EXPOSURE FOR RADIOFREQUENCY CATHETER ABLATION FOR PULMONARY VEIN ISOLATION AND
Toru Ishibashi1, Takanori Masuda1, Mamoru Kato2
1Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan.
Abstract:
To propose typical values for the arrhythmia region between pulmonary vein isolation (PVI) and nonpulmonary vein isolation (non-PVI) in Japan. A nationwide questionnaire was posted to 343 facilities, to which 125 facilities (36.4%) responded. Results is the median for PVI and non-PVI were in terms of Ka,r (317 and 196 mGy), PKA (40.8 and 26.3 Gy.cm2), FT (43.0 and 27.3 min), and CI (326 and 102 images). When comparing PVI and non-PVI procedures, there were significant differences in Ka, r, PKA, FT, and CI (p < 0.05). In other words, by classifying into two types, PVI and non-PVI, we contributed to the establishment of typical values in Japan's RFCA.