Related Experiment Video
Updated: Oct 4, 2025

Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
MultiConditionRT: Predicting liquid chromatography retention time for emerging contaminants for a wide range of
Amina Souihi1, Miklos Peter Mohai1, Emma Palm1
1Department of Environmental and Materials Chemistry, Stockholm University, Svante Arrhenius väg 16, Stockholm 106 91, Sweden.
Abstract:
Structural elucidation of compounds detected with liquid chromatography coupled to high resolution mass spectrometry is a challenging and time-consuming step in the workflow of non-targeted analysis and often requires manual validation of the results. Retention time, alongside exact mass, isotope pattern, fragmentation spectra, and collision cross-section, is valuable information for ruling out unlikely structures and increasing the confidence in others. Different approaches to predict retention times have been used previously for reversed phase chromatography and hydrophilic interaction liquid chromatography (HILIC), but application is limited to a small set of mobile phases and gradient profiles. Here, we expand the toolbox available for retention time predictions by developing a random forest regression model for predicting retention times for four column types and twenty mobile phase systems. MultiConditionRT was built using a dataset containing 78 compounds analyzed with C18 reversed phase, mixed mode, HILIC, and biphenyl columns. In addition, different eluent compositions were used: both methanol and acetonitrile were combined with different aqueous phases with pH from 2.1 to 10.0 (formic acid, acetic acid, trifluoroacetic acid, formate, acetate, bicarbonate, and ammonia). The root mean square error (RMSE) of the test set predictions was 1.55 min for C18 reversed phase, 1.79 min for mixed-mode, 1.93 min for HILIC, and 1.56 min for biphenyl column. Additionally, MultiConditionRT can be applied to different gradient profiles with a general additive model-based calibration approach. The approach of MultiConditionRT was validated externally and internally with 356 and 151 compounds respectively, yielding an RMSE of 2.68 and 2.32 min. 324 and 84 of these compounds were not in the dataset used in the model development.
More Related Videos
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
13:36Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Related Concept Videos
Chromatographic Methods: Terminology
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Instrumentation