Related Experiment Video
Updated: Oct 2, 2025

Improved UPLC-UV Method for the Quantification of Vitamin C in Lettuce Varieties Lactuca sativa L. and Crop Wild Relatives Lactuca spp.
Published on: June 30, 2020
Process Development for the Instant Quantification of Lycopene from Agricultural Produces Using Supercritical Fluid
Supriya Priyadarsani1,2, Avinash Singh Patel1,3, Yogesh Sharma4
1Division of Food Science and Postharvest Technology, ICAR-Indian Agricultural Research Institute, New Delhi 110012, India.
Abstract:
A quick, simple, and reliable isocratic ultra-performance supercritical fluid chromatography-photodiode array detector (UPSFC-DAD) method was developed and validated to determine lycopene in different horticultural products. The effects of stationary phase, co-solvent, pressure, temperature, flow rate, and mobile phase additive on the separation of lycopene were evaluated. The developed method involved BEH-2EP-2.1 × 150 mm, 5 µm as the stationary phase, and CO2/MeOH 85:15 (v/v) with formic acid as the additive at 0.10% as the mobile phase. The column temperature was maintained at 45 °C, ABPR at 1800 psi, and the mobile phase's flow rate was maintained at 1 mL/min. Under the optimized conditions, lycopene was successfully separated within 0.722 ± 0.001 min. The standard curve assayed over a range of 10 to 100 µg/mL resulted in a correlation coefficient of 0.998. The mean recoveries between 97.38% and 102.67% at different spiking levels with RSD < 2.5% were achieved. The intra and inter-day precision expressed as relative standard deviations (RSD) were found to range from 1.27% to 3.28% and from 1.57% to 4.18%, respectively. Robustness in terms of retention time (tR) and RSD were found to be 0.93 ± 0.23 min and less <2.80%, respectively. The limits of detection and quantification were 0.14 µg/mL and 0.37 µg/mL, respectively. This method was successfully applied to determine lycopene extracted from papaya, grapefruit, and bitter melon.
More Related Videos
09:50Biosynthesis of a Flavonol from a Flavanone by Establishing a One-pot Bienzymatic Cascade
Published on: August 14, 2019
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process