Radiation dose to nuclear medicine technologists when operating PET/MR compared with PET/CT
Marine Soret1,2, Jacques-Antoine Maisonobe1,2, Stéphane Payen1
1AP-HP Sorbonne Université, Hôpital Pitié-Salpêtrière, Médecine Nucléaire, F-75013 Paris, France.
Abstract:
Since 2010, positron emission tomography/magnetic resonance (PET/MR) has been increasingly used as clinical routine in nuclear medicine departments. One advantage of PET/MR over PET/computed tomography (CT) is the lower dose of ionising radiation delivered to patients. However, data on the radiation dose delivered to staff operating PET/MR compared with the new generation of PET/CT equipment are still lacking. Our aim was to compare the radiation dose to nuclear medicine technologists performing routine PET/MR and PET/CT in the same department. We retrospectively measured the daily radiation dose received by PET technologists over 13 months by collecting individual dosimetry measurements (from electronic personal dosimeters). Data were analysed taking into account the total number of studies performed with each PET modality (PET/MR with Signa 3T, General Electric Healthcare versus PET/CT with Biograph mCT flow, Siemens), the type of exploration (brain versus whole-body PET), the18F activity injected per day and per patient as well as the time spent in contact with patients after tracer injection. Our results show a significantly higher whole-body exposure to technologists for PET/MR compared with PET/CT (10.3 ± 3.5 nSv versus 4.7 ± 1.2 nSv per18F injected MBq, respectively;p< 0.05). This difference was related to prolonged contact with injected patients during patient positioning with the PET/MR device and MR coil placement, especially in whole-body studies. For an equal injected activity, radiation exposure to PET technologists for PET/MR was twice that of PET/CT. To minimise the radiation dose to staff, efforts should be made to optimise patient positioning, even in departments with extensive PET/CT experience.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...