Related Experiment Video
Updated: Sep 26, 2025

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Predictors for the detection of arrhythmia requiring pacemaker/ICD implantation-Results from a loop recorder study
Fabienne Kreimer1, Assem Aweimer2, Julian Felix Backhaus1
1Cardiology and Rhythmology, University Hospital St. Josef-Hospital Bochum, Ruhr University Bochum, Bochum, Germany.
Background:
There are few large studies on which factors are associated with the occurrence of arrhythmias. Implantable loop recorders (ILR) are useful in detecting arrhythmia due to prolonged and continuous ECG monitoring. Therefore, the aim of this study is to identify and evaluate clinical characteristics and ECG parameters for predicting arrhythmias requiring pacemaker/ICD implantation by analyzing a study cohort with ILR.
Methods:
This bicentric study comprised a study cohort of 451 patients (mean age 64 ± 16 years, 209 women) receiving ILR implantation between 2011 and 2021. Patients were followed up on a 3 monthly outpatient interval. All arrhythmias with a pacemaker or ICD indication were considered clinically relevant. The primary study endpoint was the detection of clinically relevant arrhythmia.
Results:
During a follow up of 678 ± 392 days, a clinically relevant arrhythmia was detected in 81 of 451 patients (18%). Multivariate analysis revealed five independent risk factors: coronary artery disease (HR 1.954, CI 1.077-3.546, p = .028), atrial fibrillation (HR 2.253, CI 1.201-4.228, p = .011), previous syncope (HR 6.404, CI 3.202-12.808, p < .001), right bundle branch block (HR 4.370, CI 2.215-8.621, p < .001) and left bundle branch block (HR 2.685, CI 1.116-6.461, p = .028). Our risk model, based on these independent predictors, divided the study cohort into patients with low (2%), intermediate (18%), medium (34%), and high (45%) risk for clinically relevant arrhythmia.
Conclusion:
By the use of ILR, a clinically relevant arrhythmia has been detected in almost one fifth of the study cohort. In addition, clinical and electrocardiographic parameters were shown to be suitable predictors of clinically relevant arrhythmia.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias V: Evaluating Dysrhythmias
Holter Monitor: 24-Hour Monitoring
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...