Related Experiment Video
Updated: Sep 22, 2025

Remote Sensing Evaluation of Two-spotted Spider Mite Damage on Greenhouse Cotton
Published on: April 28, 2017
Early Detection of Grapevine (Vitis vinifera) Downy Mildew (Peronospora) and Diurnal Variations Using Thermal Imaging
Bar Cohen1,2, Yael Edan2, Asher Levi1
1Agricultural Research Organization, Agricultural Engineering, P.O. Box 15159, Rishon Le Zion 7528809, Israel.
Abstract:
Agricultural industry is facing a serious threat from plant diseases that cause production and economic losses. Early information on disease development can improve disease control using suitable management strategies. This study sought to detect downy mildew (Peronospora) on grapevine (Vitis vinifera) leaves at early stages of development using thermal imaging technology and to determine the best time during the day for image acquisition. In controlled experiments, 1587 thermal images of grapevines grown in a greenhouse were acquired around midday, before inoculation, 1, 2, 4, 5, 6, and 7 days after an inoculation. In addition, images of healthy and infected leaves were acquired at seven different times during the day between 7:00 a.m. and 4:30 p.m. Leaves were segmented using the active contour algorithm. Twelve features were derived from the leaf mask and from meteorological measurements. Stepwise logistic regression revealed five significant features used in five classification models. Performance was evaluated using K-folds cross-validation. The support vector machine model produced the best classification accuracy of 81.6%, F1 score of 77.5% and area under the curve (AUC) of 0.874. Acquiring images in the morning between 10:40 a.m. and 11:30 a.m. resulted in 80.7% accuracy, 80.5% F1 score, and 0.895 AUC.
More Related Videos
07:08Identification of Novel Regulators of Plant Transpiration by Large-Scale Thermal Imaging Screening in Helianthus Annuus
Published on: January 30, 2020
08:41A Rapid Laser Probing Method Facilitates the Non-invasive and Contact-free Determination of Leaf Thermal Properties
Published on: January 7, 2017
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...