Related Experiment Video
Updated: Sep 5, 2025

Iris Fixation via External Pentagram Suturing
Published on: May 5, 2022
Cable tie technique for securing scleral fixation suture to intraocular lens
Youngsub Eom1,2, Young Joo Lee1, Seo Yeon Park3
1Department of Ophthalmology, Korea University Ansan Hospital, Gyeonggi-do, Republic of Korea.
Purpose:
To report a new flanged intrascleral fixation technique for subluxated or dislocated intraocular lens (IOL) with c-loop or double c-loop haptics (cable tie fixation method).
Observations:
We introduced a cable tie fixation method using 6-0 polypropylene for subluxated multifocal IOL with C-loop or double C-loop haptics. After passing the 6-0 polypropylene monofilament under the optic-haptic junction, the other end of the strand was taken out of the eye after passing it above the optic-haptic junction. A knot was made at one end, and the opposite strand was passed through the knot to form a loop. Both ends of the monofilament were tugged to make the loop fixed to the optic-haptic junction smaller. Both ends of the monofilament were externalized 2.5 mm posterior to the limbus using a 30 G needle. Another 6-0 polypropylene monofilament was tied to the opposite optic-haptic junction and scleral fixation was performed. While checking the IOL centration, the four ends of the 6-0 polypropylene monofilaments were heated with a cautery to form flanges.
Conclusions And Importance:
A four-flanged intrascleral fixation technique involving a cable tie-shaped loop using 6-0 polypropylene could provide stable IOL fixation without damage for subluxated or dislocated IOLs with C-loop or double C-loop haptics.