Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

UV–Vis Spectroscopy: Molecular Electronic Transitions01:16

UV–Vis Spectroscopy: Molecular Electronic Transitions

1.7K
In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this...
1.7K
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

515
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
515

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Towards Tsunami Early-Warning with Distributed Acoustic Sensing: Expected Seafloor Strains Induced by Tsunamis.

Pure and applied geophysics·2026
Same author

Draw Tower Optical Fibers with Functional Coatings and Their Possible Use in Distributed Sensor Technology.

Sensors (Basel, Switzerland)·2025
Same author

Block-based single-pixel imaging by means of the Talbot effect.

Optics letters·2025
Same author

SNR improvement in time-expanded phase-sensitive OTDR using Nyquist zone averaging.

Optics letters·2025
Same author

Spatially resolved dual-comb sensing with a single electro-optic modulator.

Optics express·2024
Same author

Brillouin expanded time-domain analysis based on dual optical frequency combs.

Light, science & applications·2024
Same journal

Long-term stabilization of intensity-difference squeezing from four-wave mixing in rubidium vapor.

Optics express·2026
Same journal

Robust 3D topography measurement of large-range high-aspect-ratio structures based on dual-domain statistical filtering in SD-OCT.

Optics express·2026
Same journal

Broadband transmissive terahertz metasurface for simultaneous quad-mode OAM multiplexing.

Optics express·2026
Same journal

Leveraging two-dimensional materials for high-sensitivity optical sensors: quasi-bound states in the continuum within hybrid metasurfaces.

Optics express·2026
Same journal

Resolution investigation for dual-spherical-wave optical scanning holographic microscopy: methods and performance.

Optics express·2026
Same journal

Robustness of parallel subnetwork-filtered diffractive deep neural networks.

Optics express·2026
See all related articles

Related Experiment Video

Updated: Aug 25, 2025

Quasi-light Storage for Optical Data Packets
07:45

Quasi-light Storage for Optical Data Packets

Published on: February 6, 2014

10.9K

Dual electro-optic comb spectroscopy using a single pseudo-randomly driven modulator.

Vicente Durán, Camilo Escobar-Vera, Miguel Soriano-Amat

    Optics Express
    |October 14, 2022
    PubMed
    Summary
    This summary is machine-generated.

    This study introduces a simplified dual-comb system using affordable generators, achieving long coherence times without complex stabilization. This advance paves the way for field-deployable dual-comb spectroscopy.

    More Related Videos

    Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy
    09:57

    Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy

    Published on: July 25, 2022

    4.0K
    Real-Time, Two-Color Stimulated Raman Scattering Imaging of Mouse Brain for Tissue Diagnosis
    10:57

    Real-Time, Two-Color Stimulated Raman Scattering Imaging of Mouse Brain for Tissue Diagnosis

    Published on: February 1, 2022

    3.2K

    Related Experiment Videos

    Last Updated: Aug 25, 2025

    Quasi-light Storage for Optical Data Packets
    07:45

    Quasi-light Storage for Optical Data Packets

    Published on: February 6, 2014

    10.9K
    Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy
    09:57

    Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy

    Published on: July 25, 2022

    4.0K
    Real-Time, Two-Color Stimulated Raman Scattering Imaging of Mouse Brain for Tissue Diagnosis
    10:57

    Real-Time, Two-Color Stimulated Raman Scattering Imaging of Mouse Brain for Tissue Diagnosis

    Published on: February 1, 2022

    3.2K

    Area of Science:

    • Optics and Photonics
    • Spectroscopy
    • Laser Physics

    Background:

    • Dual-comb spectroscopy (DCS) offers high-resolution molecular fingerprinting.
    • Conventional DCS systems often require complex stabilization and expensive components.

    Purpose of the Study:

    • To develop a simplified and cost-effective dual-comb scheme.
    • To achieve long mutual coherence times without active stabilization.
    • To assess the feasibility of a field-deployable dual-comb generator.

    Main Methods:

    • A single intensity modulator driven by pseudo-random bit sequence (PRBS) generators was employed.
    • Long interferograms were generated in the time domain.
    • Spectroscopic measurements were performed with a frequency sampling of 140 MHz.

    Main Results:

    • The dual-comb scheme demonstrated a mutual coherence time of up to 50 seconds.
    • Line spacing differences below the hertz level were achieved.
    • The system's accuracy was validated through two spectroscopic measurements.

    Conclusions:

    • The proposed simplified dual-comb architecture offers long coherence and high precision.
    • The system eliminates the need for stabilization feedback loops or self-correction algorithms.
    • The scheme shows significant potential for implementing field-deployable dual-comb generators.