Related Experiment Video
Updated: Aug 18, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
On-line solid phase extraction-ultra high performance liquid chromatography-quadrupole/Orbitrap high resolution mass
Xueyan Gao1, Yuxin Wang2, Dawei Chen2
1NHC Key Laboratory of Food Safety Risk Assessment, Food Safety Research Unit (2019RU014) of Chinese Academy of Medical Science, China National Center for Food Safety Risk Assessment, Beijing 100021, China; College of Veterinary Medicine, China Agricultural University, Beijing 100193, China.
Abstract:
A rapid, high-performance, and accurate on-line TurboFlow ultra high performance liquid chromatography-quadrupole/Orbitrap high resolution mass spectrometry method was developed for the analysis of 46 per- and polyfluoroalkyl substances (PFAS), including 17 perfluoroalkylcarboxylic acids, 15 perfluoroalkylsulfonates, 3 fluorinated telomer sulfonates, 2 perfluoroalkyl unsaturated carboxylates, 2 perfluorooctanesulfonamidoacetic acid, 3 perfluorooctanesulfonamides, hexafluoropropylene oxide-dimer acid, ammonium 4,8-dioxa-3H-perfluorononanoate, 6:2 chlorinated polyfluorinated ether sulfonate (Cl-PFESA), and 8:2 Cl-PFESA, in human serum. The TurboFlow column, mobile phase, sample injection volume, loading flow rate, and elution time were optimized. The linearities of matrix calibration curves, method limits of quantification, accuracy and precision were investigated for method validation. Serum samples (50 μL) were precipitated with acetonitrile and directly injected into the system. The method showed good linearity (R2 > 0.99), satisfactory recoveries (matrix-spiked recoveries range: 68.9%-115.7%), good precision (relative standard deviation ranges: 1.2%-12.1%) and a low method limit of quantification (0.1-1 ng mL-1). The developed method is rapid, accurate and convenient for large-scale biomonitoring of PFAS in humans. Fifty real serum samples from China were analyzed and the results showed that br-perfluorooctanesulfonate (PFOS) accounted for approximately 30% of the ∑PFOS in serum, which suggested there was high exposure to 6:2 Cl-PFESA.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
07:06Investigating Long-Distance Transport of Perfluoroalkyl Acids in Wheat via a Split-Root Exposure Technique
Published on: September 28, 2022
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors