Simple and fast determination of tetrodotoxin in human plasma based on hydrophilic-interaction/ion-exchange
Liang Xin1, Yan Liang1, Shuangshuang Yang1
1Central Laboratory, Shanghai Xuhui Central Hospital/Zhongshan-Xuhui Hospital, Fudan University, Shanghai, China; Shanghai Engineering Research Center of Phase I Clinical Research & Quality Consistency Evaluation for Drugs, Shanghai, China; Shanghai Institute of Clinical Mass Spectrometry, Shanghai, China.
Abstract:
In this study, we developed and validated a simple, fast and sensitive LC-MS/MS method for the measurement of tetrodotoxin (TTX) in human plasma. Three HILIC-type solid phase extraction (SPE) carriers (PSA, silica, Siphila i HILIX) with different stationary phase functional groups were compared. The Siphila i HILIX SPE plate containing multi-carboxyl groups was finally selected due to obviously better extraction recovery of TTX (about 80% of recovery from plasma samples) than the other two and no significant matrix effects were observed, which was speculated to have mixed-mode synergistic effects of hydrophilic interaction and ion exchange. 100μL plasma sample was precipitated rapidly with acetonitrile containing 1% trichloroacetic acid, and filtrates were loaded onto Siphila i HILIX 96 well SPE plate. After washed with 95% acetonitrile, TTX was eluted with 200μL of 50% acetonitrile containing 1% trichloroacetic acid. 2μL of elution solution was directly injected into LC-MS/MS and the total run time on a BEH amide column was 4.5 min. The method avoids the evaporation and ultrafiltration processes which is simple and timesaving (<30 min). TTX and internal standard (arginine-15N4) were monitored in positive mode using m/z 320.3→162.2 (quantification transition for TTX), 320.3→284.1 (confirmation transition for TTX) and 179.2→63.0 (transition for IS), respectively. The method was linear in the range of 0.1-20 ng/mL for TTX with the low limit of quantification (S/N > 10) of 0.1 ng/mL; the intra- and inter-assay accuracies were in the range of 98.5%-99.8% (relative standard deviations, RSDs ≤ 5.92%) and 98.8-99.5% (RSDs ≤ 6.23%), respectively. Biases of spiking analysis were ranged from -7.00% to 7.43% for healthy human plasma samples (RSDs ≤ 8.83%) and from -5.00% to 3.93% for hemolytic, high triglyceride, high cholesterol and high bilirubin plasma samples (RSDs ≤ 6.40%), which proved the good anti-interference property of the method. The results showed that the method is sensitive, accurate, specific, reliable, and can be used to monitor the concentration of TTX in plasma to meet the needs of clinical research and poisoning screening.
More Related Videos
09:36Author Spotlight: Discovering New Alkaloids in Plants with Advanced Mass Spectrometry Techniques
Published on: March 8, 2024
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Types of Detectors
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
