Acoustic monitoring of an aircraft auxiliary power unit
Umair Ahmed1, Fakhre Ali1, Ian Jennions1
1Integrated Vehicle Health Management Centre, School of Aerospace, Transport & Manufacturing Cranfield University, Bedfordshire, MK43 0AL, UK.
Abstract:
In this paper, the development and implementation of a novel approach for fault detection of an aircraft auxiliary power unit (APU) has been demonstrated. The developed approach aims to target the proactive identification of faults, in order to streamline the required maintenance and maximize the aircraft's operational availability. The existing techniques rely heavily on the installation of multiple types of intrusive sensors throughout the APU and therefore present a limited potential for deployment on an actual aircraft due to space constraints, accessibility issues as well as associated development and certification requirements. To overcome these challenges, an innovative approach based on non-intrusive sensors i.e., microphones in conjunction with appropriate feature extraction, classification, and regression techniques, has been successfully demonstrated for online fault detection of an APU. The overall approach has been implemented and validated based on the experimental test data acquired from Cranfield University's Boeing 737-400 aircraft, including the quantification of sensor location sensitivities on the efficacy of the acquired models. The findings of the overall analysis suggest that the acoustic-based models can accurately enable near real-time detection of faulty conditions i.e., Inlet Guide Vane malfunction, reduced mass flows through the Load Compressor and Bleed Valve malfunction, using only two microphones installed in the periphery of the APU. This study constitutes an enabling technology for robust, cost-effective, and efficient in-situ monitoring of an aircraft APU and potentially other associated thermal systems i.e., environmental control system, fuel system, and engines.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Conservation of AC Power
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Pulse Assessment Sites