Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Editorial: Advanced functional materials, structures, and devices for advancing human healthcare applications.

Frontiers in chemistry·2026
Same author

Author Correction: Far-field phonon coupling in valley metamaterial circuits.

Nature communications·2026
Same author

Droplet Actuation on Gradient Electrowetting Surface.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

Experimental and Numerical Study of the Hydrothermal Performance of Micro Pin Fin Heat Sinks with Streamwise-Varying Height.

Materials (Basel, Switzerland)·2026
Same author

The Influence of Mask Modification on Microneedle Strength in Deep X-Ray Lithography.

Micromachines·2026
Same author

Far-field phonon coupling in valley metamaterial circuits.

Nature communications·2025

Related Experiment Video

Updated: Aug 8, 2025

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets
08:20

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets

Published on: February 22, 2016

10.4K

Cost-Effective Droplet Generator for Portable Bio-Applications.

Lin Du1, Yuxin Li1, Jie Wang2

  • 1School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai 200433, China.

Micromachines
|February 25, 2023
PubMed
Summary
This summary is machine-generated.

This study introduces a cost-effective droplet generator for biochemical analysis. The device produces consistent nanoliter (nL) droplets independent of external flow rates, simplifying sample handling.

Keywords:
capillary numberlab chipmicrodropletsqueezing model

More Related Videos

A Femtoliter Droplet Array for Massively Parallel Protein Synthesis from Single DNA Molecules
10:45

A Femtoliter Droplet Array for Massively Parallel Protein Synthesis from Single DNA Molecules

Published on: June 20, 2020

10.4K
Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics
07:57

Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics

Published on: November 10, 2014

7.9K

Related Experiment Videos

Last Updated: Aug 8, 2025

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets
08:20

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets

Published on: February 22, 2016

10.4K
A Femtoliter Droplet Array for Massively Parallel Protein Synthesis from Single DNA Molecules
10:45

A Femtoliter Droplet Array for Massively Parallel Protein Synthesis from Single DNA Molecules

Published on: June 20, 2020

10.4K
Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics
07:57

Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics

Published on: November 10, 2014

7.9K

Area of Science:

  • Biochemistry
  • Medical Diagnostics
  • Microfluidics

Background:

  • Precise division of aqueous samples into droplets is crucial for biochemical and medical analyses.
  • Existing droplet generation methods often require strict control over external flow conditions and driving pressure.

Purpose of the Study:

  • To design and propose a cost-effective droplet generator for biochemical applications.
  • To investigate the relationship between capillary components and liquid flow rates in droplet generation.

Main Methods:

  • Development of a droplet generator with two symmetric tubes.
  • Analysis of droplet size dependency on generator dimensions, not external flow rates.
  • Verification of droplet generation principle using a dropper as a pressure source.

Main Results:

  • Generated droplet size is primarily determined by generator dimensions.
  • Achieved consistent nanoliter (nL) droplet generation with a relative standard deviation (RSD) of approximately 9.80%.
  • Demonstrated robustness and rapidity of the droplet generation principle across a wide range of flow rates (over 57.79% difference).

Conclusions:

  • The proposed droplet generator offers a simple, cost-effective solution for biochemical and medical analysis.
  • The device's independence from precise external flow control enhances its practicality for various droplet-based applications.
  • This technology shows significant potential for advancing microfluidic and lab-on-a-chip systems.