Effects of aluminium chloride added to common patch test substances
Lisbeth Rosholm Comstedt1, Ingrid Siemund1, Jakob Dahlin1
1Department of Occupational and Environmental Dermatology, Skåne University Hospital, Lund University, Malmö, Sweden.
Background:
A modulating effect of aluminium regarding type IV reactions might exist but has not been further investigated.
Objectives:
The aim of this study was to investigate the effect on patch test reactions when adding aluminium chloride hexahydrate (Al-Cl) to common test preparations.
Materials And Methods:
Al-Cl in different concentrations was added to nickel sulphate 15.0% aqua (Ni), methylisothiazolinone 0.2% aqua (MI) and fragrance mix I 10.0% aqua/ethanol (FM I). The Ni preparations were tested in 120 consecutive patients. MI and FM I were tested in participants known to have contact allergy to the respective allergen. McNemar's test was used to decide which Ni preparation had the highest sensitivity. Wilcoxon signed-rank test was used to calculate pairwise comparison in summarized test score for the preparations with MI and FM I.
Results:
Adding Al-Cl 20.0%/30.0% to Ni identified twice as many patients with contact allergy to nickel compared to Ni without Al-Cl. Adding Al-Cl 20.0%/10.0% to MI, decreased the patch test reactivity compared to MI without Al-Cl. No differences in patch reactivity were noticed when adding Al-Cl to FM I.
Conclusion:
Al-Cl 20.0% or 30.0% seems to enhance the patch test reactivity to Ni 15.0% aqua.
Related Concept Videos
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Toxic Reactions: Overview
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...