Heterogeneous breast phantom for computed tomography and magnetic resonance imaging
Gameel Saleh1, Ashraf Abuelhaija2, Budour Alfaris1
1Department of Biomedical Engineering, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia.
Abstract:
In this article, a heterogeneous multimodal anthropomorphic breast phantom with carcinoma is introduced to meet the response of the natural breast tissue when imaged using ionizing and non-ionizing machines. The skin, adipose, fibroglandular, pectoral muscle, and carcinoma tissue were mimicked. A T1-weighted breast magnetic resonance image with BI-RADS I tissue segmentation was used for molds creation. The tissue-mimicking materials (TMMs) were tailored in terms of their elemental composition weight fractions and their response to ionization radiation parameters. These are the mass attenuation coefficient (MAC), electron density (ne) and effective atomic number (Zeff). The behaviour of the TMMs, when exposed to a wide range of ionization radiation energy, was investigated analytically and numerically using X-COM. The achieved results showed an excellent agreement with the corresponding properties of the natural breast elemental compositions as reported by the International Commission on Radiation Units and Measurements (ICRU). The MAC of the TMMs and the ICRU-based breast tissue were found to be consistent. The maximum percentage of error in ne and Zeff amounts to only 2.93% and 5.76%, respectively. For non-ionizing imaging, the TMMs were characterized in term of T1 and T2 relaxation times. Using our preclinical MRI unit, the TMMs relaxation times were measured and compared to the natural tissue. The fabricated phantom was validated experimentally using CT, MRI, and Mammographic machines. The achieved images of the TMMs were in alignment with the real tissue in terms of CT HU values and grayscale colors. T1W and T2W images on MRI revealed the expected contrast between TMMs as in natural tissue.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
Related Concept Videos
Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...