Influence of isofocal intraocular lenses on objective refraction based on autorefraction and aberrometry
Lidia Pérez-Sanz1, Carla Charbel2, Francisco Poyales3
1Miranza IOA, C/Galileo 104, 28003, Madrid, Spain. lidia.perez@miranza.es.
Purpose:
To evaluate and compare the objective refractions obtained by autorefraction and aberrometry under different lighting conditions with an isofocal intraocular lens (Isopure, BVI medical, Liége, Belgium) compared to a monofocal control lens (Micropure, BVI medical, Liége, Belgium) with the same platform and material.
Methods:
Prospective, comparative and randomized study on patients undergoing cataract surgery and bilateral isofocal or monofocal IOL implantation. A total of 44 subjects were randomly assigned to either the isofocal group (n = 22) or the Micropure (n = 22). Manifest refraction (MR) was always performed under the same lighting conditions for all the patients. For objective refraction the autorefractor KR8800 and the aberrometer OPD-Scan III (Nidek Inc., Tokyo, Japan.) were used. For each eye included in the study, six result sets were collected: MR, AR (autorefraction measured with the autorefractor), WF-P and WF-M (Zernike-coefficients-based objective refraction, photopic and mesopic pupil size), OPD-C and OPD-M (autorefraction measured with the aberrometer in photopic and mesopic conditions).
Results:
The mean sphere for MR was 0.03 ± 0.32D for the Isopure group and 0.24 ± 0.22D for the monofocal group (p = 0.013). For the Isopure group, Friedman analysis showed statistically significant differences for sphere measured with WF-P (p = 0.035), WF-M (p = 0.018) and OPD-M (p = 0.000), and SE measured with OPD-M (p = 0.004). In the Micropure lens group, the Friedman analysis showed differences for all values studied (p < 0.05). Correlation coefficients showed that AR is the objective method with the strongest correlation values for all components of refraction for both groups.
Conclusion:
The modification of the surfaces of the isofocal lens does not have a negative impact on the refraction obtained by AR compared to a standard monofocal intraocular lens.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Focusing of Light in the Eye
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Glaucoma: Overview