Related Experiment Video
Updated: Jul 30, 2025

Tracking Infiltration Front Depth Using Time-lapse Multi-offset Gathers Collected with Array Antenna Ground Penetrating Radar
Published on: May 1, 2018
Design and Implementation of Three-Channel Drainage Pipeline Ground Penetrating Radar Device
Maoxuan Xu1, Feng Yang1, Rui Yan2
1School of Mechanical Electronic and Information Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China.
Abstract:
In order to solve the current problems that conventional video inspection can only detect, as an internal pipeline defect and drainage pipeline radar inspection device detects in a single direction and at radar frequency in water pipeline defect detection, a three-channel drainage pipeline ground penetrating radar (GPR) inspection device was designed and developed, the assembly and commissioning of the device prototype were completed, and an actual engineering test application was carried out. Focusing on the problem that the detection direction and depth of the single-channel detection device are limited, a three-channel drainage pipeline GPR inspection device is designed to realize the synchronous detection of the inside of the pipeline, the pipeline body, and the external environment of the pipeline, improving the detection depth and efficiency. According to the design scheme of the three-channel drainage pipeline GPR inspection device, the assembly of the device prototype was completed. The device contains three radar channels, the top of the main frequency of the antenna is 1.4 GHz, the two sides are 750 MHz, the video camera has a pixel count of 4 million, and the positioning accuracy is less than 1 mm, the waterproof grade is IP68, the detection accuracy of pipe deformation (slope) is 0.1°, the detection depth outside the pipe is 1.2 m, and the detection accuracy of corrosion thickness is 15 mm. In a practical application of the device, the Jianguomenqiao sewage pipeline in Beijing, China, was tested, resulting in the discovery of 87 defects, including 39 loose soil areas at the bottom of the pipe exterior, 40 void areas, and 8 cavities.
Related Concept Videos
Design Example: Design of an Irrigation Channel
Design Example: Maintaining Level of an Embankment
Design Example: Alignment of a Road Line Using GIS
Taping Over Different Ground Profiles
Field Application of Global Positioning System
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device

