Standing Pelvic Tilt Is Associated With Dynamic Pelvic Tilt During Running When Measured by 3-Dimensional Motion
Madison S Mach1, Kyle T Ebersole1, Hayley E Ericksen1
1Department of Rehabilitation Sciences and Technology, University of Wisconsin-Milwaukee, Milwaukee, WI,USA.
The palpation meter (PALM) is not a valid tool for measuring standing pelvic tilt (PT) compared to 3D motion analysis. However, standing PT measurements may offer insights into dynamic PT during running.
Area of Science:
- Biomechanics
- Kinesiology
- Sports Medicine
Background:
- Standing pelvic tilt (PT) is biomechanically linked to injury risks like dynamic knee valgus.
- Limited research exists on the relationship between standing PT and dynamic PT.
- The criterion validity of the palpation meter (PALM) for measuring standing PT against 3D motion analysis is not well-established.
Purpose of the Study:
- To determine the criterion validity of the PALM for measuring standing PT.
- To identify the relationship between standing PT and dynamic PT during running.
Main Methods:
- Twenty-five participants (10 males, 15 females) had their standing PT measured using the PALM and 3D motion analysis.
- Dynamic PT variables were assessed at initial contact and toe-off during running.
- Statistical analysis examined the relationship between the two measurement tools and between standing and dynamic PT.
Main Results:
- No significant relationship was found between standing PT measurements from the PALM and 3D motion analysis, indicating the PALM is not a valid alternative.
- Significant, large positive correlations were observed between standing PT and dynamic PT at both initial contact (r = .751) and toe-off (r = .761).
Conclusions:
- The PALM is not a valid tool for assessing standing pelvic tilt when compared to 3D motion analysis.
- Clinicians can utilize standing PT measurements to gain insights into dynamic PT, potentially guiding decisions for further biomechanical assessments during running analysis.